The Challenge

High maintenance and downtime costs, electrical equipment failures and unpredictable power surges are greatly affecting your production and business profitability. It is necessary to find a way to upgrade, improve, and monitor the electrical system.

What We Can Do

We can help by providing you with devices that monitor the equipment performance to evaluate its full potential and identify system vulnerabilities. We can also simulate an existing electrical system and implement NETA-certified maintenance procedures to increase efficiency; reducing downtime, risk and consumption, maximizing power factor and ultimately cost.

Brand Comparison Chart

Preventive Maintenance Data
Completed Diagnostic Solutions For Primary And Secondary Systems
Condition- Based Maintenance
Trivia
inquire now

Product Features

Key Benefits

doblePDS100
  • Can identify and locate defects using RFI technology
  • For non-invasive routine surveys of substations
  • Ideal for every service or test team
  • Advanced user-friendly diagnostic tool
  • Perfect tool for a Condition Based Maintenance (CBM) program
  • Learn More...
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance
  • Effective & critical communication at the right place and time
M700M7000
  • World's Most Complete And Most Powerful Auto- Insulation Analyzer
  • Automatic Power Apparatus Test Equipment
  • Dramatic Reduction In Off Line Test Procedures
  • HV Power Factor
  • HV DC Resistance
  • Polarization Index
  • Tip-Up
  • Dielectric Frequency
  • 3 Phase Lv TTR
  • 3 Phase Lr
  • 3 Phase Winding Resistance Test
  • Primary Injection
  • Secondary Injection
  • Ductor
  • UOHM Meter & More
  • Learn More...
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance,
  • Effective & critical communication at the right place and time
idd-lg (1)IDD
  • Online Condition- Based Maintenance For C1 to C2 Transformers Bushings.
  • Plan Bushing Replacement In A Proactive Management Approach.
  • Bushing Current Waveform Capture Measure Leakage Current Magnitude And Relative Phase Angles.
  • Monitor Up To 12 Bushings
  • Links To Online DGA Systems
  • Display Alert Locally And Remotely.
  • Learn More...
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance
  • Effective & critical communication at the right place and time
5400M5400
  • Detect Hidden Transformer Defects
  • Core Movements
  • Winding Deformation And Displacement
  • Faulty Core Grounds
  • Partial Winding Collapse
  • Broken Or Loosened Clamping Structures
  • Shortened Turns And Open Windows
  • Learn More...
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance
  • Effective & critical communication at the right place and time
DelphiDelphi–online
  • Online And Portable DGA Instrument
  • Single Value Input
  • High Accurancy And Repeatability
  • Micro-Pump Circulation
  • Online Alarms And Indications
  • Communication Options Available
  • Learn More...
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance
  • Effective & critical communication at the right place and time
mp4000M4100 4th Gen
  • World standard and pioneer for insulation Power Factor Test
  • 5 Comprehensive Test Procedures In One Compact Chasis
  • The World's Most Accurate Test Apparatus
  • 12KV IPF Capacitance Testing To Asses Insulation Condition And Dielectric Loss
  • Two-Year Warranty
  • Learn More...
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance,
  • Effective & critical communication at the right place and time

Product Features

Key Benefits

DAPPER® Studies
  • Generate better designs by comparing alternatives quickly.
  • Improve accuracy with DAPPER’s rigorous solution methods.
  • Save time by sharing a common project database and interface.
  • Improve consistency with standard design libraries.
  • Design safer systems by comparing calculations with short circuit and continuous ratings.
  • Communicate designs effectively with presentation quality graphics, reports, and equipment schedules.

Product Features

Key Benefits

UntitledMFM- 10
  • Testing, Prelocation, and pinpointing of shefaults
  • Test voltage up to 10vkv DC
  • Up to 750 mA continuous current, also suitable for burning
  • Adjustable current limiter
  • Bipolar measurement for highest accuracy
  • Only one single removable HV connection cable
  • Easy-Go operation via jogdial and touch screen
  • Automatic measurement and protocolling
  • Learn More...
  • Ensures of a safe
  • Reliable & economical electrical system & Uninterrupted Operations
  • Effective & Critical communication at the right place and time
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance
vlfVLF CR Series
  • VLF, DC and sheath fault testing in one device
  • Portable thanks to two-part construction
  • High test capacitance
  • Integrated discharge system
  • Reporting
  • Learn More...
  • Ensures of a safe
  • Reliable & economical electrical system & Uninterrupted Operations
  • Effective & Critical communication at the right place and time
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance
Surgeflex:SPG32Surgeflex/SPG32
  • Cable fault location system with TELEFLEX TECHNOLOGY (Cable Radar)
  • High Surge Energy for effective pinpoiting
  • Symmetrical / Unsymmetrical reflection measurement
  • Arc reflection Method
  • Impulse current decoupling method
  • Intermittent Fault Location
  • Learn More...
  • Ensures of a safe
  • Reliable & economical electrical system & Uninterrupted Operations
  • Effective & Critical communication at the right place and time
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance
Model T30EModel T30E
  • Designed for detection of low ohmic resistance faults in low,medium,and high voltage cables
  • Very high near end solution
  • Two signals input for direct line comparison
  • High dynamic range with distance related gain
  • Display of 3 Traces
  • Memory of 100 Traces
  • Learn More...
  • Ensures of a safe
  • Reliable & economical electrical system & Uninterrupted Operations
  • Effective & Critical communication at the right place and time
  • Preventive maintenance data
  • Complete diagnostic solutions for primary and secondary systems
  • Condition-based maintenance

Product Features

Key Benefits

saassdSuperdri® Systems (SDS Series)
  • Unique Construction – Specifically designed for transformer oil dehydration
  • High Capacity – Process up to 5,000 gallons of oil or more with a single cartridge
  • Efficient – Single pass water removal to less than 10 ppm total water, or better.
  • Versatile – Models available to fit most industry standard housings.
  • Safe – Will not remove oxidation inhibitors
  • Cost Effective – Process transformer oil for less than 5¢ per gallon
  • Learn More...
  • Condition-Based Maintenance
UntitledSuperdri® (SD Series)
  • The SDS20 System with Superdri® cartridges can be used for oil processing situations where removal of dissolved water in insulating oil is necessary.
  • Use the SDS20 System to process oil used to fill new distribution and EHV transformers. Avoids the need for heat and vacuum systems to dry the oil
  • Filter and dehydrate transformer oil used to fill existing transformers after repair or service
  • Use the SDS20 System to enable oil to meet moisture critical ASTM D-1816 dielectric strength requirements
  • Purify oil used for circuit breakers and other high voltage apparatus that is sensitive to dissolved water
  • Dehydrate oil in storage tanks and tankers that have accumulated a high level of dissolved water
  • The SDS20 can be fitted with standard Aquacon® filters for routine oil maintenance work
  • Learn More...
  • Condition-Based Maintenance
aquaconAquacon® (AC Series)
  • Water absorbing "monitor" cartridges
  • Filter particulate matter and absorb water with great efficiency
  • Water capacity is ~40 x greater than 2” diameter monitor cartridges
  • Also provide protection against water slugs.
  • Learn More...
  • Condition-Based Maintenance
TDS5Transformer Dry-out Systems (TDS® Series)
  • The TDS® oil processing system is designed to allow a transformer under load to dry itself out
  • The on-line dryout process is designed for safe, unattended, 24-hour operation.
  • Learn More...
  • Condition-Based Maintenance